Should you clean a boiler while it is running or during shutdown?

Jörg Beer ·

Both approaches have a role to play, but on-load boiler cleaning, carried out while the boiler is running, should form the backbone of any effective cleaning strategy. Shutdown cleaning remains necessary for deep maintenance, but relying on it alone leads to efficiency losses, accelerated wear and unplanned downtime between service intervals. The questions below unpack the key differences, trade-offs and practical considerations that help you choose the right approach for your plant.

What actually happens to a boiler if it is never cleaned during operation?

If a boiler is never cleaned during operation, fouling accumulates progressively on heat transfer surfaces, reducing thermal efficiency and increasing fuel consumption. Over time, deposits harden into clinker formations, corrosion accelerates beneath the fouling layer and the risk of forced shutdown rises significantly. The furnace alone accounts for roughly 50% of total heat transfer in a boiler, making deposit build-up there particularly damaging.

The process is gradual but compounding. Early-stage fouling creates an insulating layer between the combustion gases and the heat transfer surface. The boiler must burn more fuel to achieve the same steam output, which raises operating costs and CO₂ emissions simultaneously. As deposits thicken, the problem intensifies: flue gas temperatures rise, downstream components such as superheaters and economisers face higher thermal loads and the risk of tube failures increases.

In Waste-to-Energy and biomass plants, the situation is often more severe than in conventional coal-fired boilers. Fuel composition varies, chlorine and alkali compounds in the flue gas promote aggressive corrosion and deposits tend to be unevenly distributed across heating surfaces. Without regular cleaning during operation, these plants face a cycle of declining efficiency, rising maintenance costs and shortened equipment life.

What is the difference between on-load cleaning and shutdown cleaning?

On-load boiler cleaning is performed while the boiler is running at normal operating conditions, using tools such as sootblowers, water cannons or rapping systems to remove deposits continuously or at regular intervals. Shutdown cleaning takes place when the boiler is taken offline, allowing manual or mechanical access to surfaces that cannot be reached safely during operation.

On-load cleaning: continuous deposit control

On-load cleaning systems work by directing a cleaning medium, steam, air or water, at fouled surfaces while the boiler remains in service. The goal is to prevent deposits from hardening and accumulating to a level that impairs performance. Because cleaning happens in real time, fouling is managed rather than allowed to build up between shutdowns. Modern demand-driven approaches go further by cleaning only where and when deposits actually require it, based on sensor data and diagnostic monitoring rather than fixed schedules.

Shutdown cleaning: deep access and inspection

Shutdown cleaning provides access to areas that on-load systems cannot reach effectively, including surfaces that require physical inspection, manual descaling or replacement of worn components. It is also the point at which the cleaning systems themselves are serviced. Shutdown cleaning is thorough but infrequent, typically tied to planned maintenance outages, which means it cannot address fouling that develops between intervals.

Which boiler cleaning method is better for reducing unplanned downtime?

On-load cleaning is significantly more effective at reducing unplanned downtime than relying on shutdown cleaning alone. By continuously managing fouling during operation, on-load systems prevent the deposit build-up that most commonly forces emergency shutdowns, clinker falls, tube blockages and corrosion-driven failures that develop when surfaces are left uncleaned between planned outages.

Unplanned shutdowns in industrial boiler systems are rarely caused by a single sudden failure. More often, they result from gradual deterioration that was not addressed in time. Heavy slagging in the furnace can cause large clinker formations to break away and damage the hopper area. Fouled superheater surfaces can cause steam temperature deviations that trigger protective shutdowns. Blocked economiser passages reduce heat recovery and push flue gas temperatures beyond acceptable limits.

On-load cleaning interrupts this deterioration cycle. When deposits are removed regularly during operation, surfaces stay cleaner, thermal performance stays stable and the conditions that lead to forced outages are far less likely to develop. The result is greater plant availability and more predictable maintenance planning.

Can on-load cleaning fully replace shutdown cleaning?

No. On-load cleaning cannot fully replace shutdown cleaning, but it can substantially reduce the frequency and intensity of what shutdown cleaning needs to address. The two approaches are complementary: on-load systems handle continuous deposit management during operation, while shutdown cleaning covers deep maintenance, inspection and access to areas that cannot be safely cleaned while the boiler is running.

Some surfaces and components require physical access that is only possible when the boiler is offline. Tube bundles in tight configurations, catalyst beds and certain air preheater sections may need manual attention that no on-load system can replicate. Additionally, the on-load cleaning equipment itself requires periodic inspection and servicing during shutdowns.

What effective on-load cleaning does achieve is a meaningful reduction in the workload and duration of shutdown cleaning. When deposits have been consistently managed during operation, surfaces are in better condition when the boiler comes offline. This shortens the time needed for shutdown maintenance and reduces the risk of discovering severe corrosion or structural damage that has developed undetected beneath heavy fouling.

What factors determine the right cleaning strategy for a specific boiler?

The right boiler cleaning strategy depends on fuel type, deposit characteristics, boiler design, operating flexibility requirements and the specific zones within the boiler that are most prone to fouling. There is no universal answer: each plant requires an assessment of these factors to determine which combination of cleaning methods and frequencies will deliver the best results.

  • Fuel type and quality: Biomass and waste fuels produce more variable and aggressive deposits than conventional fuels. Plants burning mixed or changing fuel streams need cleaning systems that can adapt to shifting deposit patterns rather than following a fixed schedule.
  • Deposit characteristics: Loose, dry deposits respond well to steam- or air-based sootblowers. Heavy, sticky slagging in the furnace typically requires water-based cleaning with higher impact energy. Corrosive deposits in superheater zones need targeted approaches that avoid thermal shock to tube surfaces.
  • Boiler zone: Different zones have different fouling profiles. The furnace, superheater/reheater, economiser and air preheater each require cleaning methods suited to their operating temperatures, surface geometry and deposit types.
  • Operating flexibility: Plants that operate flexibly, varying load, fuel mix or output, experience more variable deposit formation. A demand-driven cleaning approach, guided by real-time diagnostics, is more effective in these conditions than a fixed cleaning interval.
  • Availability targets: Plants with high availability requirements benefit most from on-load cleaning systems that minimize the need for unplanned interventions.

How often should boiler cleaning be performed during normal operation?

There is no single correct frequency for boiler cleaning during operation. The optimal interval depends on how quickly deposits form, which is driven by fuel composition, combustion conditions and the specific heating surface in question. In practice, the most effective approach is demand-driven cleaning, where cleaning is triggered by actual deposit conditions rather than a fixed time schedule.

Traditional fixed-interval cleaning schedules were designed for predictability, not efficiency. They clean surfaces that may not yet need it and can miss areas where deposits are forming faster than expected. In plants burning variable fuels, a common situation in Waste-to-Energy and biomass operations, deposit rates can shift significantly from one operating period to the next, making fixed schedules a poor fit.

Demand-driven cleaning uses sensor data and diagnostic monitoring to identify where deposits are building up and how quickly. Cleaning is then applied where it is actually needed, at the right time and with the right intensity. This approach reduces unnecessary cleaning cycles, lowers wear on cleaning equipment and ensures that fouling is addressed before it reaches a level that impairs performance or risks damage.

For plants without diagnostic monitoring, a practical starting point is to establish baseline cleaning intervals based on operational experience and then adjust based on observed performance indicators, flue gas temperatures, steam output, pressure differentials across heating surfaces and fuel consumption trends. These signals provide a reliable indication of whether cleaning frequency needs to increase or can be reduced.

How Clyde Bergemann supports your boiler cleaning strategy

We have been developing and supplying on-load boiler cleaning systems for more than 60 years, working across power generation, Waste-to-Energy, biomass and other industrial processes. Our approach is built around the specific conditions of each plant rather than off-the-shelf solutions.

Our Clyde Bergemann boiler efficiency solutions cover every zone of the boiler, from furnace cleaning with water cannons and wall blowers to sootblowers for superheaters, economisers and air preheaters, as well as rapping systems for loose deposits in facilities with varying fuels. We also offer SMART Clean, our demand-driven cleaning philosophy that uses real-time diagnostics to clean based on actual deposit conditions rather than fixed schedules.

What we offer in practice:

  • On-load cleaning systems tailored to your fuel type, deposit profile and boiler design
  • SMART Clean diagnostics and controls for demand-driven, targeted cleaning
  • Coverage across all boiler zones: furnace, superheater/reheater, economiser, air preheater and catalyst/absorber
  • Cleaning solutions for flexible operation with changing fuel mixtures or variable fuel quality
  • Spare parts supply and service support to keep systems running under demanding conditions
  • Training for your team delivered by our own engineers

If you want to review your current cleaning strategy or assess whether your existing systems are matched to your operating conditions, we are happy to help. Get in touch to discuss your plant’s specific situation.