The most effective methods for on-load boiler cleaning depend on where deposits form and how severe they are, but the core approaches are sootblowing, water-based cleaning systems, and rapping systems. Each targets a different zone of the boiler and a different type of fouling. The sections below answer the most common questions about how these methods work, when to use them, and how to get the most out of them.
How does fouling actually reduce boiler efficiency?
Fouling reduces boiler efficiency by forming an insulating layer on heat transfer surfaces, which forces the combustion gases to carry more heat out of the boiler rather than transferring it to the steam cycle. Even a thin deposit layer measurably increases flue gas exit temperatures and raises fuel consumption to maintain the same steam output.
The furnace alone accounts for roughly half of total heat transfer in a boiler. When slagging builds up on furnace walls, the steam generator loses efficiency, clinker formations can damage the hopper area, and corrosion rates accelerate beneath the deposit layer. In superheaters, reheaters, and economisers, fouling compounds the problem by restricting gas flow and creating uneven temperature profiles that stress tube materials.
In Waste-to-Energy and biomass plants, deposits tend to be distributed unevenly across heating surfaces because fuel composition, moisture content, and combustion conditions vary continuously. This inhomogeneous distribution makes blanket cleaning schedules inefficient and often insufficient. Targeted, demand-driven cleaning is far more effective at maintaining heat transfer without over-stressing surfaces.
What are the main types of on-load boiler cleaning systems?
The main types of on-load boiler cleaning systems are sootblowers, water-based cleaning systems, and rapping systems. Sootblowers use steam or air as the cleaning medium, water-based systems use pressurised water jets or sprays, and rapping systems use mechanical impulse without any cleaning medium. Each type suits different boiler zones and deposit characteristics.
A practical way to understand the options is by boiler zone:
- Furnace and empty passes: Water cannons, shower cleaning systems, and wall blowers handle heavy slagging on membrane walls. Steam-based wall blowers are the conventional choice; water-based systems are better suited to heavier or stickier deposits.
- Superheater and reheater: Retractable sootblowers and part-retractable sootblowers are the standard solution, using steam or air to dislodge ash deposits from tube bundles.
- Economiser: Rotating element sootblowers, oscillating sootblowers, and rake sootblowers cover this zone, with rapping systems as an alternative where no cleaning medium is preferred.
- Air preheater and gas-gas heater: Rake sootblowers, part-retractable sootblowers, and water-based jetblowers are used depending on deposit type and access constraints.
Controls and diagnostics systems sit across all zones, enabling intelligent cleaning that responds to actual deposit conditions rather than fixed time intervals.
How does sootblowing work and when is it most effective?
Sootblowing works by directing a high-velocity jet of steam or compressed air at fouled heat transfer surfaces while the boiler remains in operation. The kinetic energy of the jet dislodges ash and deposit particles, which then fall into the hopper or are carried out with the flue gas stream. It is most effective against loose, dry, or lightly bonded deposits.
A retractable sootblower inserts a lance tube into the flue gas path, rotating as it travels so that two high-performance nozzles cover a helical cleaning pattern. Travel distances can reach up to 10 metres, and the systems are rated for flue gas temperatures up to 1,400°C. Part-retractable versions are used in superheater and reheater areas where full insertion is not practical.
For targeted cleaning of specific segments with heavier fouling, oscillating sootblowers concentrate cleaning energy on a defined area rather than sweeping the full tube bank. Rotating element sootblowers handle lighter fouling in lower-temperature zones such as economisers, where flue gas temperatures stay below 500°C and the blowing element rotates in place without axial movement.
Sootblowing is least effective when deposits are sticky, molten, or chemically bonded to tube surfaces. In those cases, water-based cleaning systems deliver significantly more removal force.
What causes slagging in waste-to-energy and biomass boilers?
Slagging in Waste-to-Energy and biomass boilers is caused by the partial melting of ash particles that then adhere to furnace walls and heating surfaces. The primary drivers are high alkali and chlorine content in the fuel, which lower the ash melting point, combined with the high radiant heat flux in the furnace zone.
Municipal solid waste and biomass fuels contain significantly higher concentrations of potassium, sodium, and chlorine than coal. These elements form low-melting-point compounds that become sticky at furnace temperatures and bond strongly to tube surfaces. As more particles land on the initial deposit layer, the slag grows thicker and harder to remove.
Variable fuel quality makes the problem more complex. Mixed waste streams change composition from load to load, and biomass fuels vary by season, source, and moisture content. This variability means that slagging intensity and location shift constantly, which is why fixed-schedule cleaning often fails to keep pace with actual deposit build-up.
Combustion conditions also play a role. Incomplete combustion, poor air distribution, and fluctuating load profiles all contribute to uneven temperature fields that concentrate slagging in specific areas of the furnace rather than distributing it evenly.
Which on-load cleaning method is best for heavy or sticky deposits?
Water-based cleaning systems are the most effective method for heavy or sticky deposits. Water delivers far greater impact energy than steam or air at comparable pressures, and it also provides a thermal shock effect that helps crack and dislodge bonded slag layers. For the most severe slagging in large furnaces, a water cannon with precise positioning control is the strongest available solution.
Water cannons for targeted furnace cleaning
A water cannon uses a precisely controlled linear drive to create a meander-shaped jet pattern across the side and opposite furnace walls. The control system positions the jet accurately so that cleaning energy is concentrated where deposits are actually forming rather than sweeping uniformly across clean and fouled surfaces alike. This targeted approach protects tube surfaces from unnecessary thermal stress while maximising deposit removal.
Shower cleaning systems for full-coverage applications
Where full-coverage cleaning of the furnace and empty passes is needed, a shower cleaning system mounted on the boiler roof lowers into the furnace while spraying water in a continuous 360-degree pattern. An inverted umbrella nozzle or multi-jet nozzle distributes water across the full circumference as the unit descends, making it suitable for all incinerator sizes. This approach works well in plants where deposit distribution is broad rather than concentrated in specific zones.
For membrane wall surfaces with heavy slagging, water-based wall blowers are an alternative to steam-based wall blowers when deposit hardness or thickness exceeds what steam jets can reliably remove.
How often should on-load boiler cleaning systems be activated?
On-load boiler cleaning systems should be activated based on actual deposit conditions rather than a fixed time schedule. Demand-driven cleaning, triggered by real-time measurements of heat transfer performance or deposit thickness, consistently outperforms interval-based cleaning in both cleaning effectiveness and surface protection.
Fixed cleaning schedules were the industry standard for decades, but they have two significant weaknesses. When deposits build up faster than the schedule anticipates, cleaning arrives too late and efficiency losses accumulate. When the schedule runs cleaning on surfaces that are already clean, the repeated thermal and mechanical stress shortens tube life unnecessarily.
Demand-driven cleaning addresses both problems by using instrumentation and control systems to monitor where deposits are forming and how quickly. Flux sensors, for example, measure heat transfer rates at specific points in the boiler and signal when cleaning is needed in that zone. The cleaning system then activates only the relevant blowers or water jets, at the right time and with the right intensity.
In practice, the optimal cleaning frequency varies by fuel type, load profile, and boiler design. Waste-to-Energy plants burning mixed municipal waste typically require more frequent furnace cleaning than coal-fired plants because of the higher alkali and chlorine content in the fuel. Biomass plants with variable fuel quality face similar challenges and benefit particularly from adaptive cleaning control that responds to fuel changes in real time.
How Clyde Bergemann supports effective boiler cleaning
We have been developing and supplying boiler cleaning systems for more than a century, and our portfolio covers every zone of the boiler with solutions matched to the actual deposit conditions your plant faces. Whether you are dealing with light ash in an economiser or heavy slagging in a Waste-to-Energy furnace, we offer the right technology and the engineering expertise to apply it correctly.
- Full zone coverage: Our systems address furnaces, superheaters, reheaters, economisers, air preheaters, and gas-gas heaters with steam, air, and water-based cleaning technologies as well as rapping systems that require no cleaning medium at all.
- Demand-driven cleaning: Our SMART Clean platform activates cleaning based on real deposit conditions, reducing unnecessary blowing cycles and protecting tube surfaces from avoidable stress.
- Water-based furnace cleaning: We were among the first in the industry to apply water as a cleaning medium for furnace walls, and our SMART Cannon and Shower Clean systems represent the current state of the art for heavy and sticky deposits.
- Fuel flexibility: Our systems are designed to handle variable fuel quality and mixed fuel operation, which is particularly relevant for Waste-to-Energy and biomass plants where combustion conditions shift continuously.
- Global service support: We provide inspection, maintenance, and spare parts support in over 130 countries, with experienced engineers who understand the operating conditions your equipment faces.
You can find a full overview of our Clyde Bergemann boiler efficiency solutions on our website. If you want to discuss the specific fouling challenges in your plant, get in touch and we will help you identify the most suitable approach.
Related Articles
- 7 sootblower maintenance mistakes that shorten equipment service life
- How does waste composition affect boiler fouling?
- What happens when a boiler cleaning system fails mid-operation?
- How much downtime can a missing boiler cleaning system cause?
- What is slagging in industrial boilers and how is it different from fouling?